電控消防水炮安裝運輸不合格的后果
來源:http://www.xintli.net/ 日期:2023-04-17
電控消防水炮為電動有線和無線遙控兩種直流驅動控制方式,實現操作人員能夠在遠距離直接控制消防炮射水角度,能很好的保護滅火人員的人身。下面
川消小編來講講電控消防水炮安裝運輸不合格的后果吧。
The electric fire water monitor adopts two DC drive control methods: electric wired and wireless remote control, which enables operators to directly control the water injection angle of the fire monitor from a long distance, effectively protecting the personal safety of firefighters. Next, let's talk about the consequences of unqualified installation and transportation of electronic fire water monitors.
1、若不沖洗,則不僅會使電動閥關閉不嚴,還會使雜物堵塞水炮炮嘴,進而影響水炮射程和流量。
1. If not flushed, not only will the electric valve not be tightly closed, but it will also cause debris to block the nozzle of the water cannon, thereby affecting the range and flow rate of the water cannon.
2、若與其他系統共用一個泵房系統,則水炮管網壓力達不到額定工作壓力
2. If sharing a pump room system with other systems, the pressure of the water cannon pipeline network cannot reach the rated working pressure
3、若不裝,則管道內有雜質會使電動閥關閉不嚴,進而出現長期漏滴水現象以及會堵住炮口。這會造成后期維護難度很大。
3. If not installed, impurities in the pipeline will cause the electric valve to close loosely, leading to long-term water leakage and blockage of the gun mouth. This will make maintenance difficult in the later stage.
4、若裝反,則會造成電動閥開關相反,調試水炮時現場控制箱顯示關閥,實際是開閥,造成誤噴水。
4. If installed in the wrong direction, it will cause the electric valve to switch in the opposite direction. When debugging the water cannon, the on-site control box shows that the valve is closed, but in reality, it is open, causing incorrect water spraying.
5、若安裝距離過近,電動閥轉動時,擋板會被法蘭卡住導致關閉不嚴、電動閥燒壞,以及射水流量不夠
5. If the installation distance is too close, the baffle will be stuck by the flange when the electric valve rotates, resulting in loose closure, burnt electric valve, and insufficient water injection flow rate

6、若太高,則不方便現場施工和日后檢修維護。
6. If it is too high, it will be inconvenient for on-site construction and future maintenance.
7、20-80L/S為DN100;100-120L/S為DN150;150-200L/S為DN200;其他流量請聯系廠家,若小于該標準,則不符合消防驗收標準。
7. 20-80L/S is DN100; 100-120L/S is DN150; 150-200L/S is DN200; For other flow rates, please contact the manufacturer. If it is less than this standard, it does not meet the fire acceptance standards.
8、20-80L/S為DN100;100-120L/S為DN150;150-200L/S為DN200;其他流量請聯系廠家會造成水炮轉動或噴水顫動避免造成法蘭之間漏水,損壞水炮電子元件
8. 20-80L/S is DN100; 100-120L/S is DN150; 150-200L/S is DN200; For other flow rates, please contact the manufacturer to avoid water leakage between flanges and damage to the electronic components of the water cannon, which may cause rotation or water jet vibration
9、水炮控制箱控制系統為電路板時,須在安裝水炮控制箱前將地址碼設定好,撥碼方式:1號炮撥1,2號炮撥2,3號炮撥1、2,4號炮撥3,以此類推,控制箱撥碼為二進制。否則將會影響后期水炮調試增加不必要的麻煩。
9. When the control system of the water cannon control box is a circuit board, the address code must be set before installing the water cannon control box. The dialing method is: 1 for gun 1, 2 for gun 2, 1, 2 for gun 3, 3 for gun 4, and so on. The dialing code of the control box is binary. Otherwise, it will affect the later water cannon debugging and increase unnecessary trouble.
10、水炮控制箱控制系統為繼電器時,則無需編碼。會影響水炮的正常旋轉
10. When the control system of the water cannon control box is a relay, there is no need for coding. It will affect the normal rotation of the water cannon
11、若距吊頂太近,則炮嘴仰起噴水會打到頂棚上。
11. If it is too close to the suspended ceiling, the nozzle will lift up and spray water onto the ceiling.
12、若不是,則容易造成通訊故障(RS485故障);視頻模糊。
12. If not, it is easy to cause communication failure (RS485 failure); Video blurring.
That's all for the consequences of unqualified installation and transportation of electronic fire water monitors. If you have any doubts or needs, please feel free to visit our website at any time http://www.xintli.net Conduct consultation to understand!